Surface treatment of polymers for the fabrication of all-polymer MEMS devices

Jiheng Zhao, Debra A. Sheadel, Wei Xue

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Polymer microelectromechanical systems (MEMS) have received considerable attention due to their low cost, remarkable biocompatibility, and high flexibility when compared to glass and silicon devices. However, the fabrication process of all-polymer MEMS devices can be complicated and often requires a special group of techniques. In particular, different types of polymers possess different properties in terms of surface chemistry and hydrophilicity, making device assembly a challenging task. In this paper, we demonstrate the fabrication of an all-polymer microfluidic device through the investigation of the essential surface treatment methods. An SU-8-SU-8-polydimethylsiloxane (PDMS) sandwiched structure is used in this research because SU-8 enables alignment capabilities during the fabrication process. It can also be easily extended to other lithography-compatible processes. Both untreated SU-8 and PDMS are hydrophobic and they have different surface chemistry properties, so surface modifications are necessary. Three critical surface treatment steps are used in our process. The first step is to treat the first SU-8 layer with low-power (10 W) oxygen plasma, making its surface hydrophilic. This step enables the uniform coating of the second SU-8 layer. The next surface treatment is on the second SU-8 layer. Both oxygen plasma (40 W) etching and diluted 3-aminopropyltriethoxysilane (APTES, a silane solution) coating are needed. APTES introduces amine (SiNH 2) groups on the surface. The last treatment step is to introduce silanol (SiOH) groups on PDMS using oxygen plasma. These surface treatment steps are critical in the fabrication process and can determine the quality of the final device. The knowledge obtained from this research can enable the development of novel all-polymer MEMS devices for biomedical applications.

Original languageEnglish (US)
Pages (from-to)43-49
Number of pages7
JournalSensors and Actuators, A: Physical
Volume187
DOIs
StatePublished - Nov 1 2012

Fingerprint

surface treatment
microelectromechanical systems
MEMS
Surface treatment
Polymers
oxygen plasma
Fabrication
fabrication
polymers
Oxygen
Surface chemistry
Plasmas
chemistry
coatings
Silanes
Coatings
microfluidic devices
Hydrophilicity
biocompatibility
Silicon

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Instrumentation
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrical and Electronic Engineering

Cite this

@article{b0a08e476acd4114837e76cef4e6543f,
title = "Surface treatment of polymers for the fabrication of all-polymer MEMS devices",
abstract = "Polymer microelectromechanical systems (MEMS) have received considerable attention due to their low cost, remarkable biocompatibility, and high flexibility when compared to glass and silicon devices. However, the fabrication process of all-polymer MEMS devices can be complicated and often requires a special group of techniques. In particular, different types of polymers possess different properties in terms of surface chemistry and hydrophilicity, making device assembly a challenging task. In this paper, we demonstrate the fabrication of an all-polymer microfluidic device through the investigation of the essential surface treatment methods. An SU-8-SU-8-polydimethylsiloxane (PDMS) sandwiched structure is used in this research because SU-8 enables alignment capabilities during the fabrication process. It can also be easily extended to other lithography-compatible processes. Both untreated SU-8 and PDMS are hydrophobic and they have different surface chemistry properties, so surface modifications are necessary. Three critical surface treatment steps are used in our process. The first step is to treat the first SU-8 layer with low-power (10 W) oxygen plasma, making its surface hydrophilic. This step enables the uniform coating of the second SU-8 layer. The next surface treatment is on the second SU-8 layer. Both oxygen plasma (40 W) etching and diluted 3-aminopropyltriethoxysilane (APTES, a silane solution) coating are needed. APTES introduces amine (SiNH 2) groups on the surface. The last treatment step is to introduce silanol (SiOH) groups on PDMS using oxygen plasma. These surface treatment steps are critical in the fabrication process and can determine the quality of the final device. The knowledge obtained from this research can enable the development of novel all-polymer MEMS devices for biomedical applications.",
author = "Jiheng Zhao and Sheadel, {Debra A.} and Wei Xue",
year = "2012",
month = "11",
day = "1",
doi = "10.1016/j.sna.2012.08.018",
language = "English (US)",
volume = "187",
pages = "43--49",
journal = "Sensors and Actuators, A: Physical",
issn = "0924-4247",
publisher = "Elsevier",

}

Surface treatment of polymers for the fabrication of all-polymer MEMS devices. / Zhao, Jiheng; Sheadel, Debra A.; Xue, Wei.

In: Sensors and Actuators, A: Physical, Vol. 187, 01.11.2012, p. 43-49.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Surface treatment of polymers for the fabrication of all-polymer MEMS devices

AU - Zhao, Jiheng

AU - Sheadel, Debra A.

AU - Xue, Wei

PY - 2012/11/1

Y1 - 2012/11/1

N2 - Polymer microelectromechanical systems (MEMS) have received considerable attention due to their low cost, remarkable biocompatibility, and high flexibility when compared to glass and silicon devices. However, the fabrication process of all-polymer MEMS devices can be complicated and often requires a special group of techniques. In particular, different types of polymers possess different properties in terms of surface chemistry and hydrophilicity, making device assembly a challenging task. In this paper, we demonstrate the fabrication of an all-polymer microfluidic device through the investigation of the essential surface treatment methods. An SU-8-SU-8-polydimethylsiloxane (PDMS) sandwiched structure is used in this research because SU-8 enables alignment capabilities during the fabrication process. It can also be easily extended to other lithography-compatible processes. Both untreated SU-8 and PDMS are hydrophobic and they have different surface chemistry properties, so surface modifications are necessary. Three critical surface treatment steps are used in our process. The first step is to treat the first SU-8 layer with low-power (10 W) oxygen plasma, making its surface hydrophilic. This step enables the uniform coating of the second SU-8 layer. The next surface treatment is on the second SU-8 layer. Both oxygen plasma (40 W) etching and diluted 3-aminopropyltriethoxysilane (APTES, a silane solution) coating are needed. APTES introduces amine (SiNH 2) groups on the surface. The last treatment step is to introduce silanol (SiOH) groups on PDMS using oxygen plasma. These surface treatment steps are critical in the fabrication process and can determine the quality of the final device. The knowledge obtained from this research can enable the development of novel all-polymer MEMS devices for biomedical applications.

AB - Polymer microelectromechanical systems (MEMS) have received considerable attention due to their low cost, remarkable biocompatibility, and high flexibility when compared to glass and silicon devices. However, the fabrication process of all-polymer MEMS devices can be complicated and often requires a special group of techniques. In particular, different types of polymers possess different properties in terms of surface chemistry and hydrophilicity, making device assembly a challenging task. In this paper, we demonstrate the fabrication of an all-polymer microfluidic device through the investigation of the essential surface treatment methods. An SU-8-SU-8-polydimethylsiloxane (PDMS) sandwiched structure is used in this research because SU-8 enables alignment capabilities during the fabrication process. It can also be easily extended to other lithography-compatible processes. Both untreated SU-8 and PDMS are hydrophobic and they have different surface chemistry properties, so surface modifications are necessary. Three critical surface treatment steps are used in our process. The first step is to treat the first SU-8 layer with low-power (10 W) oxygen plasma, making its surface hydrophilic. This step enables the uniform coating of the second SU-8 layer. The next surface treatment is on the second SU-8 layer. Both oxygen plasma (40 W) etching and diluted 3-aminopropyltriethoxysilane (APTES, a silane solution) coating are needed. APTES introduces amine (SiNH 2) groups on the surface. The last treatment step is to introduce silanol (SiOH) groups on PDMS using oxygen plasma. These surface treatment steps are critical in the fabrication process and can determine the quality of the final device. The knowledge obtained from this research can enable the development of novel all-polymer MEMS devices for biomedical applications.

UR - http://www.scopus.com/inward/record.url?scp=84868529904&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84868529904&partnerID=8YFLogxK

U2 - 10.1016/j.sna.2012.08.018

DO - 10.1016/j.sna.2012.08.018

M3 - Article

AN - SCOPUS:84868529904

VL - 187

SP - 43

EP - 49

JO - Sensors and Actuators, A: Physical

JF - Sensors and Actuators, A: Physical

SN - 0924-4247

ER -