TY - JOUR
T1 - Development of a dual-electrospray ionization source with in-line absorbance-based voltage control
AU - Foster, Samuel W.
AU - Parker, Deklin
AU - Piccolo, Christopher
AU - Will, Matthew
AU - Grinias, James P.
N1 - Publisher Copyright:
© 2023, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2023/7
Y1 - 2023/7
N2 - Emitter tip arrays for electrospray ionization have been used for a variety of MS sample introduction purposes, including detection of multiple sample eluent streams and improved accuracy through parallel infusion of an internal standard. User control is typically required for targeted application of high voltage to specific channels to maximize analyte signal and minimize other background signals. In this communication, an automated approach to applying electrospray voltage only when a detectable analyte is present is described. An in-line absorbance detector is used to identify the presence of an analyte in the fluidic path between the sample introduction valve and the mass spectrometer. A Raspberry Pi-controlled system is then used to apply high voltage to a downstream emitter tip at the MS inlet following a delay volume between the detectors. Demonstration of this technique on two parallel sample channels is reported, including a pulsed voltage application to maximize signal when analytes elute on each channel simultaneously.
AB - Emitter tip arrays for electrospray ionization have been used for a variety of MS sample introduction purposes, including detection of multiple sample eluent streams and improved accuracy through parallel infusion of an internal standard. User control is typically required for targeted application of high voltage to specific channels to maximize analyte signal and minimize other background signals. In this communication, an automated approach to applying electrospray voltage only when a detectable analyte is present is described. An in-line absorbance detector is used to identify the presence of an analyte in the fluidic path between the sample introduction valve and the mass spectrometer. A Raspberry Pi-controlled system is then used to apply high voltage to a downstream emitter tip at the MS inlet following a delay volume between the detectors. Demonstration of this technique on two parallel sample channels is reported, including a pulsed voltage application to maximize signal when analytes elute on each channel simultaneously.
UR - http://www.scopus.com/inward/record.url?scp=85146927072&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85146927072&partnerID=8YFLogxK
U2 - 10.1007/s00216-023-04564-3
DO - 10.1007/s00216-023-04564-3
M3 - Article
C2 - 36707447
AN - SCOPUS:85146927072
SN - 1618-2642
VL - 415
SP - 4147
EP - 4152
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
IS - 18
ER -