TY - JOUR
T1 - Design and analysis of a novel parallel mechanism for prosthetic knee wear test simulators
AU - Daeinejad, Fatemeh S.
AU - Farahmand, Farzam
AU - Durali, Mohammad
AU - Abedinnasab, Mohammad H.
N1 - Publisher Copyright:
© 2017, The Korean Society of Mechanical Engineers and Springer-Verlag Berlin Heidelberg.
PY - 2017/2/1
Y1 - 2017/2/1
N2 - Using a parallel mechanism in the wear test simulators of prosthetic knees provides an easy access to the femoral and tibial components during tests. Moreover, because of its higher accuracy and load capacity, in comparison with serial mechanisms, it allows simulation of heavier tasks, such as climbing stairs, to be performed. This paper describes a new 3 Degree of freedom (DoF) spatial 2T1R (T: Translational DoF; R: Rotational DoF) parallel mechanism, for reproducing the force and motion of the tibial component of the knee prostheses in a wear test simulator. Kinematics and dynamics analysis of the mechanism indicated that it can satisfy the required DoFs, workspace and load capacity prescribed in the standard. Also, evaluation of the performance of the mechanism using the simMechanics toolbox of MATLAB revealed that it can reproduce the prescribed forces/torques with relatively high accuracy. However, the mechanism’s force outcomes were found to be affected by inaccuracies in mounting the prosthesis components, although less than the previous serial simulators. In comparison of the different possible architectures, a lateral leg angulation of 45 degrees provided the best efficacy, considering the size of actuators, the overall size of the mechanism and the accessibility of the test sample.
AB - Using a parallel mechanism in the wear test simulators of prosthetic knees provides an easy access to the femoral and tibial components during tests. Moreover, because of its higher accuracy and load capacity, in comparison with serial mechanisms, it allows simulation of heavier tasks, such as climbing stairs, to be performed. This paper describes a new 3 Degree of freedom (DoF) spatial 2T1R (T: Translational DoF; R: Rotational DoF) parallel mechanism, for reproducing the force and motion of the tibial component of the knee prostheses in a wear test simulator. Kinematics and dynamics analysis of the mechanism indicated that it can satisfy the required DoFs, workspace and load capacity prescribed in the standard. Also, evaluation of the performance of the mechanism using the simMechanics toolbox of MATLAB revealed that it can reproduce the prescribed forces/torques with relatively high accuracy. However, the mechanism’s force outcomes were found to be affected by inaccuracies in mounting the prosthesis components, although less than the previous serial simulators. In comparison of the different possible architectures, a lateral leg angulation of 45 degrees provided the best efficacy, considering the size of actuators, the overall size of the mechanism and the accessibility of the test sample.
UR - http://www.scopus.com/inward/record.url?scp=85013197089&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85013197089&partnerID=8YFLogxK
U2 - 10.1007/s12206-017-0141-1
DO - 10.1007/s12206-017-0141-1
M3 - Article
AN - SCOPUS:85013197089
SN - 1738-494X
VL - 31
SP - 885
EP - 892
JO - Journal of Mechanical Science and Technology
JF - Journal of Mechanical Science and Technology
IS - 2
ER -